[ 457.483095] nipa-hw-worker: [39/53] drivers/net/hw:ntuple.py: all 24 failed cases match known bad, skipping retry [ 457.483283] nipa-hw-worker: [39/53] drivers/net/hw:ntuple.py: rc=1 (0.8s) [ 457.483299] nipa-hw-worker: [40/53] Running drivers/net/hw:pause.py [ 457.489393] kselftest: Running tests in drivers/net/hw [ 457.555906] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 457.572305] ethtool (10583) used greatest stack depth: 11896 bytes left [ 457.588188] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 458.543210] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 458.547196] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 458.549746] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 458.558454] ethtool (10595) used greatest stack depth: 11872 bytes left [ 458.561765] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 458.564011] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 458.574761] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 458.575826] i40e 0000:e1:00.1 ens1f1np1: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 458.604195] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 459.477701] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 459.481236] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 459.484468] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 459.495811] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 459.498005] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 459.498723] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 459.509205] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 460.412220] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 460.416121] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 460.418845] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 460.430157] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 460.432288] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 460.433001] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 460.443781] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 461.353531] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 461.357415] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 461.360124] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 461.379120] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 461.383135] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 461.389230] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 461.389919] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 462.288068] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX/TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 462.291606] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 462.324248] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 462.334380] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 463.222515] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX/TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 463.226152] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 463.249355] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 463.262954] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 463.262962] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 463.290424] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 464.150247] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 464.153847] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 464.155022] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 464.180901] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 464.202586] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 465.084766] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 465.088360] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 465.089524] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 465.121563] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 465.147423] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 466.019247] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 466.023218] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 466.024364] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 466.061516] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 466.082516] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 466.953810] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 466.957692] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 466.958840] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 466.991086] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 467.016443] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 467.888329] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 467.891984] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 467.893079] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 467.930573] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 467.951576] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 468.822837] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 468.826464] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 468.827548] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 468.860137] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 468.885463] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 469.757286] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 469.760848] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 469.761994] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 469.799474] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 469.820814] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 470.691859] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 470.695535] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 470.696650] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 470.729024] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 470.754485] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 471.626370] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 471.629893] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 471.630988] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 471.668435] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 471.689403] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 472.560810] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 472.564347] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 472.565514] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 472.598106] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 472.623494] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 473.495389] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 473.498861] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 473.500029] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 473.537643] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 473.558691] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 474.429902] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 474.433564] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 474.434738] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 474.466191] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 474.492517] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 475.364344] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 475.367813] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 475.368911] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 475.406509] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 475.427569] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 476.298906] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 476.302447] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 476.303598] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 476.336222] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 476.361537] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 477.233416] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 477.237056] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 477.238216] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 477.275407] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 477.296466] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 478.167932] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 478.171407] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 478.172566] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 478.205139] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 478.230569] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 479.102418] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 479.106428] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 479.107583] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 479.145137] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 479.166135] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 480.036961] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 480.040617] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 480.041788] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 480.074386] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 480.099566] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 480.971473] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 480.984512] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 480.985650] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 481.020989] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 481.044576] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 481.905917] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 481.909452] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 481.916867] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 481.953313] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 481.978999] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 482.840475] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 482.843957] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 482.852131] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 482.888385] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 482.913533] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 483.774989] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 483.778874] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 483.785861] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 483.822116] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 483.848057] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 484.709448] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 484.713034] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 484.720919] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1