[ 475.835966] nipa-hw-worker: [39/54] drivers/net/hw:ntuple.py: all 24 failed cases match known bad, skipping retry [ 475.836145] nipa-hw-worker: [39/54] drivers/net/hw:ntuple.py: rc=1 (0.8s) [ 475.836161] nipa-hw-worker: [40/54] Running drivers/net/hw:pause.py [ 475.842367] kselftest: Running tests in drivers/net/hw [ 475.905369] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 475.933872] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 476.763032] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 476.766601] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 476.769620] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 476.781833] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 476.784327] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 476.794564] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 476.799915] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 477.697535] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 477.701175] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 477.704087] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 477.715431] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 477.717655] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 477.718370] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 477.729071] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 478.632108] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 478.635671] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 478.638585] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 478.649860] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 478.652064] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 478.652784] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 478.663558] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 479.573403] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 479.577058] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 479.580059] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 479.599053] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 479.603067] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 479.609156] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 479.609888] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 480.507879] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX/TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 480.511495] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 480.543233] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 480.553372] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 481.442451] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX/TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 481.445996] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 481.469633] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 481.481930] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 481.481937] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 481.514558] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 482.370151] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 482.373784] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 482.374949] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 482.393150] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 482.413132] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 483.304657] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 483.308294] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 483.309463] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 483.328331] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 483.347329] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 484.239163] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 484.242801] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 484.243961] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 484.274201] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 484.290014] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 485.173605] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 485.177246] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 485.178339] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 485.212807] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 485.236283] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 486.108114] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 486.111998] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 486.113077] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 486.146495] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 486.170850] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 487.146504] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 487.150435] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 487.151522] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 487.185787] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 487.209168] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 488.081021] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 488.084928] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 488.086071] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 488.119621] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 488.143641] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 489.015522] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 489.019475] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 489.020628] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 489.054806] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 489.078186] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 489.950037] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 489.953510] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 489.954677] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 489.989178] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 490.012721] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 490.884481] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 490.888114] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 490.889275] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 490.923777] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 490.947195] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 491.819043] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 491.822688] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 491.823847] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 491.857797] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 491.881739] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 492.753561] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 492.757439] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 492.758529] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 492.792626] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 492.816234] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 493.688079] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 493.691610] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 493.692715] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 493.727006] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 493.750695] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 494.622569] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 494.626609] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 494.627759] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 494.662409] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 494.685262] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 495.557099] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 495.561002] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 495.562101] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 495.595904] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 495.619713] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 496.491599] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 496.495424] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 496.496569] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 496.530912] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 496.554290] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 497.426116] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 497.429743] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 497.430899] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 497.465204] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 497.488731] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 498.360624] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 498.364187] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 498.365350] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 498.399682] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 498.423309] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 499.295131] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 499.299039] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 499.300179] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 499.332873] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 499.351806] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 500.229581] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 500.233127] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 500.241117] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 500.272567] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 500.292583] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 501.164139] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 501.167678] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 501.174973] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 501.205057] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 501.226894] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 502.098656] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 502.102248] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 502.110121] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 502.141238] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 502.162220] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 503.033171] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 503.036797] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 503.044123] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1