[ 731.966148] nipa-hw-worker: [39/53] drivers/net/hw:ntuple.py: all 24 failed cases match known bad, skipping retry [ 731.968755] nipa-hw-worker: [39/53] drivers/net/hw:ntuple.py: rc=1 (2.2s) [ 731.968860] nipa-hw-worker: [40/53] Running drivers/net/hw:pause.py [ 732.120973] kselftest: Running tests in drivers/net/hw [ 732.656911] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 732.695317] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 733.710018] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 733.715401] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 733.737839] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 733.765238] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 733.782576] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 733.836717] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 733.878101] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 735.363927] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 735.379157] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 735.404365] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 735.426541] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 735.435573] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 735.452778] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 735.461273] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 736.402191] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 736.407730] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 736.428540] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 736.454547] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 736.470188] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 736.500018] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 736.508594] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 737.454875] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 737.460003] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 737.480229] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 737.503285] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 737.512480] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 737.530237] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 737.539425] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 738.797230] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX/TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 738.802343] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 738.866142] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 738.871357] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 739.731763] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX/TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 739.735543] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 739.787573] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 739.827086] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 739.827117] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 739.849915] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 740.970935] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 740.974728] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 740.978217] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 741.107355] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 741.127607] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 742.009270] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 742.013077] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 742.016534] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 742.151198] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 742.175822] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 743.151474] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 743.156698] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 743.159278] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 743.343511] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 743.370346] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 744.293644] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 744.297993] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 744.301669] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 744.513384] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 744.532866] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 745.539650] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 745.543421] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 745.546667] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 745.740366] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 745.759433] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 746.793137] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 746.796944] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 746.800038] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 746.995541] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 747.014994] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 747.927844] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 747.931654] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 747.934714] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 748.133900] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 748.156935] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 749.069997] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 749.075647] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 749.079215] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 749.291940] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 749.319628] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 750.315993] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 750.319801] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 750.323253] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 750.517876] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 750.544826] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 751.465679] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 751.469549] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 751.502680] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 751.703271] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 751.728557] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 752.600379] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 752.604219] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 752.606940] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 752.797632] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 752.819037] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 753.742549] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 753.746311] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 753.749431] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 753.944572] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 753.971379] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 754.884750] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 754.888555] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 754.891520] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 755.089254] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 755.113556] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 756.026903] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 756.030690] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 756.033580] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 756.275856] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 756.297268] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 757.272892] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 757.276701] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 757.279645] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 757.480218] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 757.502323] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 758.415094] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 758.418901] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 758.422186] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 758.616507] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 758.643926] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 759.557658] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 759.561455] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 759.564941] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 759.807863] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 759.828176] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 760.810765] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 760.824698] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 760.827989] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 761.035254] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 761.063269] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 762.049289] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 762.053055] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 762.056571] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 762.231670] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 762.264209] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 763.191455] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 763.195232] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 763.232290] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 763.486324] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 763.513755] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 764.437465] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 764.441242] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 764.515928] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 764.775888] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 764.801292] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 765.787315] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 765.791148] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 765.828653] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 766.094515] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 766.119981] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 767.033323] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 767.037128] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 767.075514] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1