[ 751.177061] nipa-hw-worker: [39/53] drivers/net/hw:ntuple.py: all 24 failed cases match known bad, skipping retry [ 751.179864] nipa-hw-worker: [39/53] drivers/net/hw:ntuple.py: rc=1 (2.1s) [ 751.179972] nipa-hw-worker: [40/53] Running drivers/net/hw:pause.py [ 751.320800] kselftest: Running tests in drivers/net/hw [ 751.835726] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 751.875981] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 752.893386] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 752.898404] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 752.919536] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 752.945679] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 752.988484] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 753.013594] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 753.056583] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 753.931689] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 753.935577] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 753.956954] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 753.984369] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 753.988404] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 754.009059] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 754.017692] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 754.970040] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 754.973846] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 754.995530] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 755.022363] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 755.023526] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 755.048481] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 755.056083] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 756.015262] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 756.030814] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 756.056764] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 756.081480] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 756.090643] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 756.108381] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 756.117103] i40e 0000:e1:00.0 ens1f0np0: Only speed and autoneg are supported. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 757.365209] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX/TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 757.378788] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 757.438044] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 757.443234] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 758.299605] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: RX/TX SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 758.303440] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 758.357604] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 758.396968] i40e 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 758.396994] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 758.418141] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 759.434959] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 759.438846] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 759.442436] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 759.541683] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 759.560795] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 760.473319] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 760.477178] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 760.480594] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 760.583739] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 760.608679] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 761.511636] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 761.525675] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 761.528716] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 761.770366] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 761.792330] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 762.757649] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 762.771681] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 762.783416] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 762.973686] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 762.996867] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 763.899825] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 763.906617] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 763.923875] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 764.100033] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 764.118813] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 765.042012] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 765.049196] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 765.055527] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 765.252361] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 765.271637] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 766.391850] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 766.395635] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 766.399159] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 766.597767] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 766.620687] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 767.541505] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 767.545300] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 767.548457] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 767.778266] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 767.804385] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 768.780029] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 768.783790] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 768.786738] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 768.993932] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 769.019252] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 769.922169] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 769.925938] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 769.929116] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 770.162338] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 770.182825] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 771.168248] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 771.181500] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 771.189429] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 771.390016] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 771.417823] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 772.310406] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 772.314230] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 772.317826] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 772.510073] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 772.529370] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 773.452564] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 773.456337] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 773.459695] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 773.658949] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 773.681742] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 774.594768] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 774.598512] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 774.602332] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 774.787660] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 774.813201] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 775.736910] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 775.742132] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 775.745995] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 775.990139] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 776.017643] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 776.982920] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 776.986736] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 776.990389] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 777.197797] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 777.222180] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 778.125098] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 778.128953] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 778.132494] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 778.379936] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 778.406720] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 779.371157] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 779.375124] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 779.378469] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 779.578295] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 779.600253] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 780.513312] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 780.520709] i40e 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 780.537070] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 780.699379] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 780.728494] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 781.655499] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 781.661005] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 781.695474] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 781.973399] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 781.998513] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 782.901492] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 782.905249] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 782.943275] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 783.222127] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 783.244547] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 784.147505] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 784.151291] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 784.189352] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 784.477769] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 784.501359] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 785.497365] i40e 0000:e1:00.0 ens1f0np0: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 785.501170] i40e 0000:e1:00.1 ens1f1np1: NIC Link is Up, 10 Gbps Full Duplex, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 785.538840] i40e 0000:e1:00.1 ens1f1np1: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1