[ 442.362184] nipa-hw-worker: [39/53] drivers/net/hw:ntuple.py: all 24 failed cases match known bad, skipping retry [ 442.362370] nipa-hw-worker: [39/53] drivers/net/hw:ntuple.py: rc=1 (0.8s) [ 442.362386] nipa-hw-worker: [40/53] Running drivers/net/hw:pause.py [ 442.368490] kselftest: Running tests in drivers/net/hw [ 442.608048] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 442.609897] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 443.109676] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 443.110422] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 445.209512] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 445.212686] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 445.709309] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 445.712318] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 445.809532] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 445.812003] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 446.309338] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 446.312023] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 450.506236] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 450.602789] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 451.009435] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 451.011221] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 451.112499] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 451.113366] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 451.709660] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 451.712646] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 453.801916] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 453.801968] ice 0000:e1:00.0 ens1f0np0: Autoneg did not complete so changing settings may not result in an actual change. SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 453.819703] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 454.409495] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 454.411281] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 454.506293] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 454.602876] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 455.026948] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 455.027174] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 455.101964] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 455.909776] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 456.009736] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 456.012203] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 456.528265] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 456.528514] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 456.530061] ice 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 458.612976] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 458.613844] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 459.126229] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 459.126453] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 459.127663] ice 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 461.204487] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 461.303750] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 461.709641] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 461.712670] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 461.809831] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 461.812310] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 462.309626] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 462.309787] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 462.412298] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 462.413156] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 462.927140] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 462.927386] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1