[ 419.652930] nipa-hw-worker: [39/54] drivers/net/hw:ntuple.py: all 24 failed cases match known bad, skipping retry [ 419.653135] nipa-hw-worker: [39/54] drivers/net/hw:ntuple.py: rc=1 (0.8s) [ 419.653151] nipa-hw-worker: [40/54] Running drivers/net/hw:pause.py [ 419.659155] kselftest: Running tests in drivers/net/hw [ 419.901784] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 419.903731] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 420.503054] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 420.503216] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 422.601509] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 422.603361] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 423.103269] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 423.106417] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 423.202932] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 423.205406] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 423.702743] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 423.703491] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 427.895836] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 427.996177] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 428.702819] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 428.703552] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 428.805879] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 428.806749] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 429.303076] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 429.305762] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 431.394923] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 431.413074] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 432.002873] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 432.004661] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 432.098815] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 432.196237] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 432.719274] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 432.719521] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 432.795328] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 433.303137] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 433.401579] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 433.403505] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 433.920187] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 433.920411] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 433.921857] ice 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 436.006753] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 436.007623] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 436.518994] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 436.519218] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 436.519790] ice 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 438.598259] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 438.697105] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 439.102999] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 439.106161] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 439.195377] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 439.212392] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 439.702983] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 439.703738] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 439.806070] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 439.806930] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 440.321481] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 440.321728] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1