[ 418.288687] nipa-hw-worker: [39/54] drivers/net/hw:ntuple.py: all 24 failed cases match known bad, skipping retry [ 418.288907] nipa-hw-worker: [39/54] drivers/net/hw:ntuple.py: rc=1 (0.8s) [ 418.288922] nipa-hw-worker: [40/54] Running drivers/net/hw:pause.py [ 418.295541] kselftest: Running tests in drivers/net/hw [ 418.534657] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 418.536517] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 419.036319] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 419.039484] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 421.136149] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 421.139331] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 421.635944] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 421.639127] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 421.734724] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 421.736577] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 422.236457] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 422.237209] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 426.429465] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 426.529387] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 427.236055] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 427.236799] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 427.338704] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 427.339572] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 427.836258] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 427.838913] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 429.928573] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 429.944021] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 430.536081] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 430.537871] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 430.632816] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 430.729475] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 431.252498] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 431.252637] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 431.328129] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 431.836375] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 431.936325] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 431.938806] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 432.454868] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 432.455116] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 432.456702] ice 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 434.539482] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 434.540439] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 435.854631] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 435.854880] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 435.855394] ice 0000:e1:00.0 ens1f0np0: To change autoneg please use: ethtool -s autoneg SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 437.931083] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 438.030267] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 438.436252] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 438.439413] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 438.535011] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 438.536884] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 439.036237] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 439.039375] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: None SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 439.128633] ice 0000:e1:00.0 ens1f0np0: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 439.148295] ice 0000:e1:00.1 ens1f1np1: NIC Link is Down SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1 [ 439.655227] ice 0000:e1:00.0 ens1f0np0: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.0 [ 439.655453] ice 0000:e1:00.1 ens1f1np1: NIC Link is up 100 Gbps Full Duplex, Requested FEC: RS-FEC, Negotiated FEC: RS-FEC, Autoneg Advertised: On, Autoneg Negotiated: True, Flow Control: Rx/Tx SUBSYSTEM=pci DEVICE=+pci:0000:e1:00.1